The remote agent appliance on the VM console displays messages that can help you
identify issues such as agent registration fails in OCI or an agent connected to OCI not
functioning properly.
The external interface of the remote agent appliance VM is not configured
properly. Either no DHCP lease has been acquired or no static IP configuration
is provided.
Remedy: Ensure that the VM
network adapters are connected to a valid network. Change the network settings
in the appliance configuration when the appliance is powered
off.
Appliance was unable to resolve gateway MAC address
The remote agent appliance VM is not able to
communicate with the configured default network gateway.
Remedy: Ensure that the VM
network adapters are connected to a valid network. Change the network settings
in the appliance configuration when the appliance is powered
off.
Appliance did not receive a response from DNS servers 🔗
The remote agent appliance VM is not able to receive a
response from DNS servers.
Remedy: Verify that the IP
addresses of the DNS servers are configured correctly and are available. Change
the network settings in the appliance configuration when the appliance is
powered off.
Appliance was unable to connect to a proxy IP address 🔗
The proxy settings of the remote agent appliance VM are
not configured properly.
Remedy: Verify that the proxy
IP address and port is correct and proxy server is available. Change the network
settings in the appliance configuration when the appliance is powered
off.
Appliance has not yet successfully connected to OCI 🔗
The registration attempt failed and a connection could not be established with
OCI. A network configuration issue such as a DNS lookup failure or an
interrupted registration process might have occurred.
Remedy: Review the diagnostic
messages to diagnose the network configuration issue. After the networking
configurations are updated, the appliance attempts a connection to OCI until the
date indicated, before failing permanently. A remote agent appliance with a
Creating status in the OCI console can indicate an
interrupted registration process. In some cases, you must reset or deploy a new
appliance, and attempt the registration again
Appliance has failed to register 🔗
The registration attempt has failed permanently.
Remedy: Review the diagnostic
messages for details. If the registration token has expired the registration is
not attempted further. Reset or deploy a new appliance and attempt registration
again.
Appliance has failed to authorize in the control plane 🔗
A registered remote agent appliance could not
communicate with the service control plane.
Remedy: Review the diagnostic
messages for details, and and verify that the appropriate service policies are
created. The appliance attempts to re-establish the connection until
successful..
Connection to OCI has failed 🔗
The previously registered and functioning remote agent appliance might be experiencing an
intermittent network issue.
Remedy: Review the diagnostic
messages for details. The appliance keeps retrying the connection until the date
indicated, before failing permanently.
Appliance registration has expired 🔗
The registration for a previously functioning remote agent appliance has expired.
Remedy: For security reasons,
expired registrations can't be renewed. Reset or deploy a new appliance and
register again.